Search results for "internal conversion coefficient"

showing 5 items of 5 documents

In-beam study of 253No using the SAGE spectrometer

2017

The heavy actinide nucleus 253No (Z = 102) was studied using the (S)ilicon (A)nd (Ge)rmanium (SAGE) spectrometer allowing simultaneous in-beam $\gamma$ -ray and conversion electron spectroscopy at the accelerator laboratory of the University of Jyvaskyla. Using the recoil-tagging technique, $\gamma$ -electron coincidences have allowed for the extension of the level scheme in the lower-spin region of the yrast band. In addition, internal conversion coefficient (ICC) measurements to establish the multipolarity of transitions have been performed. Measurement of the interband-intraband branching ratios supports the assignment of the Nilsson band-head configuration $9/2^{-}[734]$ assigned in pre…

PhysicsNuclear and High Energy PhysicsSpectrometer010308 nuclear & particles physicsYrastHadronElectronactinide nucleus[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciencesElectron spectroscopyNuclear physics0103 physical sciencesNuclear fusion[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Atomic physicsSAGE spectrometer010306 general physicsInternal conversion coefficientSpectroscopyThe European Physical Journal A
researchProduct

Determination of absolute internal conversion coefficients using the SAGE spectrometer

2016

A non-reference based method to determine internal conversion coefficients using the SAGE spectrometer is carried out for transitions in the nuclei of 154Sm, 152Sm and 166Yb. The Normalised-Peak-to-Gamma method is in general an efficient tool to extract internal conversion coefficients. However, in many cases the required well-known reference transitions are not available. The data analysis steps required to determine absolute internal conversion coefficients with the SAGE spectrometer are presented. In addition, several background suppression methods are introduced and an example of how ancillary detectors can be used to select specific reaction products is given. The results obtained for …

electron spectroscopyinternal conversion coefficientsilicon detectorbackground subtractionenergy reconstruction
researchProduct

Isomeric state of 80Y and its role in the rp-process

2003

The HIGISOL facility has been used to investigate carefully the isomeric transition 228.5 keV in 80Y. We have measured the electron internal conversion coefficient for this transition αK = 0.50 ± 0.07 which gives the value for half-life of “bare” isomeric state T 1/2 = 6.8 ± 0.5 s. The isomeric state should play an important role in the rp-process calculations.

Materials scienceThermodynamicsElectronState (functional analysis)rp-processNuclear isomerInternal conversion coefficientValue (mathematics)
researchProduct

Determination of absolute internal conversion coefficients using the SAGE spectrometer

2016

Abstract A non-reference based method to determine internal conversion coefficients using the SAGE spectrometer is carried out for transitions in the nuclei of 154 Sm, 152 Sm and 166 Yb. The Normalised-Peak-to-Gamma method is in general an efficient tool to extract internal conversion coefficients. However, in many cases the required well-known reference transitions are not available. The data analysis steps required to determine absolute internal conversion coefficients with the SAGE spectrometer are presented. In addition, several background suppression methods are introduced and an example of how ancillary detectors can be used to select specific reaction products is given. The results o…

Nuclear and High Energy Physicselectron spectroscopy01 natural sciencesParticle detectorInternal conversionOptics0103 physical sciences010306 general physicsInternal conversion coefficientInstrumentationsilicon detectorbackground subtractionenergy reconstructionPhysicsBackground subtractionSpectrometerta114010308 nuclear & particles physicsbusiness.industry3. Good healthComputational physicsSemiconductor detectorMeasuring instrumentbusinessRadioactive decayinternal conversion coefficientNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Isomeric state of $^{80}$Y and its role in the astrophysical rp-process

2001

5 pages, 7 figures.-- PACS nrs: 21.10.Tg; 23.20.Nx; 27.50.+e.

59 ≤ A ≤ 89 [[PACS] Properties of specific nuclei listed by mass ranges]PhysicsNuclear and High Energy Physics[PACS] Properties of specific nuclei listed by mass ranges: 59 ≤ A ≤ 89Proton[PHYS.NEXP] Physics [physics]/Nuclear Experiment [nucl-ex]010308 nuclear & particles physicsHadronElectron[PACS] Internal conversion and extranuclear effects (including Auger electrons and internal bremsstrahlung)rp-processNuclear isomer[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciences7. Clean energyNuclear physicsExcited state0103 physical sciences[PACS] Lifetimes widthsAtomic physics010306 general physicsInternal conversion coefficientExcitation
researchProduct